About 44,200 results
Open links in new tab
  1. External Static Pressure vs. Total Static Pressure | Eng-Tips

    Apr 28, 2001 · Static pressure is the one that helps us determine if the ductwork is restrictive. To measure static pressure accurately, you need to use a device called a static pressure pitot tube.

  2. ROOM STATIC PRESSURE CALCULATION | Eng-Tips

    Jan 29, 2003 · I would take the minmimum required fresh air flow and then use a weighted louver to control room air pressure (remains closed until room static pressure exceeds set-point).

  3. PSV Reaction Force Calculation - API 520 Static Pressure Term

    Aug 27, 2019 · With the outlet piping being minimal the pressure at the inside of tail pipe outlet would be nearly same as that exit of PSV nozzle which is critical pressure, I used critical …

  4. Open discharge system: Pressure value at point of discharge??

    Oct 2, 2002 · If the pressure at the discharge is 0, what is the purpose of the last term in the API 520, 4.4.1.1 formula for the reaction force (A*P) (Area at point of the outlet x static pressure at …

  5. How would you calculate the static pressure? | Eng-Tips

    May 15, 2012 · As for the static pressure of the zone in question; since this is an existing system, get a manometer and static pressure probe and measure it. What you calculate may not match …

  6. Static Efficiency in Fan | Eng-Tips

    Jan 15, 2006 · So, fan power for static pressure would be: Ns = (Volume flow * static pressure loss)/ (3600 * etas) in kW and static efficiency sould be etas = Ns/ Noutp, but looking in a data …

  7. Exhaust fan pressure requirement | Eng-Tips

    Aug 6, 2015 · Fan is usually sized or selected based on airflow (units may be cfm or lps) and external static pressure or ESP (unit is in in-wg or pa). For the static pressure, i will not use …

  8. Water Hammer Formula | Eng-Tips

    Dec 9, 2003 · Static pressure is what people are usually referring to when they ask, "What's the pressure in the pipe?" In our water hammer calculation, the valve discharges to atmospheric …

  9. Fan static pressure | Eng-Tips

    Oct 31, 2015 · Typically, fans are selected based on an external static pressure with a corresponding CFM. From there, the manufacturer will add in their internal static pressure …

  10. Elevation correction for pressure | Eng-Tips

    Jun 24, 2005 · Is such a correction necessary for my system also which has a high pressure cylinderical pipe of constant CSA? If so, is there a formula to calculate the pressure loss due …